TOP SMS Alert Gateway is designed as a cost effective remote system alert device. It monitors up to 8 dry contacts and 4 relay outputs.
Pre-defined SMS is sent to designated mobile numbers when alarm condition happens. The mobile numbers can be pre-assigned to any technician or engineers who will response to the alarm alert immediately.
Besides sending alarm messages through SMS, the respective personnel can also trigger any relay output by using SMS. The relay output can be connected to alarm device such as alarm sirens. The built-in microprocessor chip running on real-time operating system takes immediate response to any changes in both input and output condition. This helps during critical condition when immediate response is needed.
As GSM modem is embedded in the gateway, therefore it can be installed anywhere under GSM coverage.
"SMS Alert Diver" software is use to configure the gateway. Settings on the alarm conditions, alert SMS, as well as the pre-designated mobile phone number can be configure through this program. Using Ethernet as the interface, user can simply configure the gateway through LAN.
Thanks to the user-friendly configuration, NO PROGRAMMING IS NEEDED. |
 |
In the case of water level in the tank rise to SMS Alarm Zone, the level sensor will trigger the alarm to TOP1000-01 and thus send out SMS Alarm Alert to notified the personnel in charge . At the same time, TOP1000-01 can also trigger the Alarm Sirens at site if the personnel in charge did not response to the alert at a specify period.
The pre-defined personnel in-charge for this critical condition received the SMS Alarm Alert. If the personnel-in charge required to take some time to reach the site, he can choose to close the valve on the water tank by sending a SMS back to TOP1000-01. |
| Feature: |
- 8 dry contacts and trigger 4 relay outputs, thus total of 12 alarm points are available
- For every point, 1 alert, recovery and reminder SMS message can be sent to 10 designated mobile numbers
- Grouping can be pre-assigned with delay interval to technician in the 1st level and engineer in the 2nd level, etc
- Administrative rights can also be assigned to different levels of personnel.
- Events data logging
- Web-based configuration
|
|
Speed Antenna Bandwidth Operating Temperature Operation Humidity Supply Voltage Current drawn Power consumption Connection Inputs 8X Dry contact inputs
Outputs 4X Relay output
Size Weight Diagnostic LEDs Installation Method
|
10 Base-T (RJ45 port) gain 2.15dBi (JW-X-003) / 3dBi (JW-X-010) Tri-band GSM900/DCS1800/PCS1900 MHz 10°C – 50°C 5% - 90%, Non-condensing 7V to 30VDC 180mA (max) 1.2Wdc at 12VDC Screw terminal
Relay Contact TTL signal
@ 230Vac / 0.5A typical 3.0x105 operations @ 6Vdc / 0.1A typical 2.0x106 operations @ 30Vdc / 1A typical 5.0x105 operations @30Vdc / 2A typical 1.0x105 operations 130mm x 40mm x 120mm (DxWxH) 460g GSM signal, TX and RX of serial signal 35mm Din-Rail, desk mounts
|
|